30 amps: The starter version
The BLUEWAVE product family starts with a 30-amp version. It is the ideal device for smaller companies in which the consumed current and harmonic content is not too high and is not expected to increase noticeably in the foreseeable future. BLUEWAVE 30 is available from our sales partners. Technical data
50 amps: The compact version
BLUEWAVE 50 is universally applicable. In contrast to conventional devices, it only requires 30% of the volume and, with a weight of only 47 kg, is easy to handle and suitable for wall mounting. BLUEWAVE 50 is available from our sales partners. Technical data
100 amps: The generalist version
BLUEWAVE 100 has enough power to ensure good power quality for most situations. Another special feature: It is usually sufficient to compensate for harmonic content in three phases. BLUEWAVE 100 comes into play if compensation is also required on the N-type conductor. This variant will be available in a three-conductor and four-conductor version. BLUEWAVE 100 is expected to be available at the end of 2007. Technical data
BLUEWAVE 300 can be used everywhere where the large currents with a high harmonic content are transferred. Already installed in a switch cabinet, this device fulfills the IP54 degree of protection and is thus also suited for use under extreme conditions. BLUEWAVE 300 is equipped with fan cooling as standard, but water cooling is also optionally available. BLUEWAVE 300 is expected to be available at our sales partners from September 2007. Technical data
| 30 A | 50 A | 100 A | 300 A | |
| Switching frequency | 16 kHz | 16 kHz | 16 kHz | 16 kHz |
| Overload capability | 250% for 10 ms | 250% for 10 ms | 250% for 10 ms | 250% for 10 ms |
| Cooling type | Air | Air | Air | Air Optionally: water |
| Ambient temperature | 40°C/derating >55°C, 2%/K | 40°C/derating >55°C, 2%/K | 40°C/derating >55°C, 2%/K | 40°C/derating >55°C, 2%/K |
| Altitude | 1,000m/derating >4,000m, 1%/100 m | 1,000m/derating >4,000m, 1%/100 m | 1,000m/derating >4,000m, 1%/100 m | 1,000m/derating >4,000m, 1%/100 m |
Dimensions | 360x590x290 mm | 360x590x290 mm | 450x590x350 mm | 800x2000x600 mm |
| Weight | 47 kg | 47 kg | 65 kg | 325 kg |
Response time | 300 | 300 | 300 | 300 |
| Controller topology | Digital with FFT analysis | Digital with FFT analysis | Digital with FFT analysis | Digital with FFT analysis |
| Parallel operation | 5 units | 5 units | 5 units | 5 units |
| Mains frequency | 47 ... 63 Hz | 47 ... 63 Hz | 47 ... 63 Hz | 47 ... 63 Hz |
| Protection class | IP20, optionally IP 54 | IP20, optionally IP 54 | IP20, optionally IP 54 | IP 54 |
| Noise level (1 m) | 60 dBA | 60 dBA | 63 dBA | 70 dBA |